Made to the standard your consultant names — EN 1338, EN 1339/1341/1342/1343, EN 14231 / pendulum PTV-USRV ≥45 wet — manufactured in mainland China, contracted through Hong Kong, delivered to Hamad Port.
Typical clients: developers, hotel groups, landscape contractors and government projects in Doha and Lusail. Failure on this scope is usually wet slip resistance below the declared value once installed and sealed — which is what our submittal pack proves first.
YY DESIGN is a supplier and manufacturer of paving and hardscape, not a Doha-registered contractor: we fabricate in our own plants in Foshan and Ningbo, contract through our Hong Kong entity, and supply to your main contractor or installer. Price is returned as a factory unit rate plus freight to Hamad Port, so a paving and hardscape package for a Qatar project can be compared line by line against a local trader's quote instead of a lump sum. We quote projects in Doha and Lusail and hold the test reports and mill certificates that a Ministry of Municipality (MME) submission asks for. Lead time, pricing and project terms are confirmed per project against the drawing and the standard your consultant named.
Scopes we fabricate under this line: porcelain paving, natural stone paving, concrete block paving, timber decking, kerb and edging, tactile paving — each with its own fixing detail and test basis, so the submittal is prepared per scope rather than per catalogue page.
| Standard | Scope |
|---|---|
| EN 1338 | concrete blocks: ≥50 MPa mean / 45 MPa single, water absorption ≤6.5%, abrasion ≤22.5 cm³/50 cm² |
| EN 1339/1341/1342/1343 | |
| EN 14231 / pendulum PTV-USRV ≥45 wet | |
| DIN 51130 | R rating for ramps |
Reports are issued by accredited laboratories in the client's or consultant's name, so they can go straight into a Ashghal (Public Works Authority) and Kahramaa specifications package without a re-test request.
paving layout, traffic class and slip-resistance target. Send the city, the standard the consultant named, and the date the submittal is due — one page comes back with the comparison.
Yes. We design and prefabricate in mainland China, contract through our Hong Kong entity, and ship to Hamad Port. Most projects are installed by the client's contractor; we supply setting-out drawings, anchor details and a supervisor's checklist.
Primary tests: EN 1338, EN 1339/1341/1342/1343, EN 14231 / pendulum PTV-USRV ≥45 wet, DIN 51130. Local gate: Ashghal (Public Works Authority) and Kahramaa specifications. Reports are issued in the client's or consultant's name.
Production, freight and sample dispatch timings are confirmed per project in the written agreement; sample and test report sets can be prioritised where the submittal is on the critical path.
paving layout, traffic class and slip-resistance target — plus the city and the standard the consultant named. A one-page comparison is prepared after review.
R11 comes from DIN 51130, the ramp test: a person walks an oiled ramp and the angle at which they slip gives the classification, R9 being the least rough and R13 the most. R11 is a common specification for external walkways and pool surrounds. Important limit: DIN 51130 is measured on the ramp, so it describes barefoot or shoe slip on a flat-ish surface — it is not the same as the pendulum test (EN 13036-4) used for roads and outdoor paving generally, and wet-area public paving and pool decks are increasingly specified with both, and the paving pattern matters as much as the rating — a smooth large-format tile laid with tight joints sheds water differently from a textured block with a 3 mm joint.
EN 1338 is the product standard for concrete paving blocks: it sets dimensional tolerances, compressive and tensile splitting strength, water absorption, freeze-thaw resistance and slip resistance. It is a factory production control standard, so the declaration of performance matters more than a single test report — it should cover the actual block type, thickness and colour. Thickness is the variable that most often gets substituted on site, and it is the one that determines whether the pavement takes the traffic class it was designed for.
Efflorescence is soluble salts migrating to the surface as moisture evaporates. It is a symptom, not a defect of the stone. The causes worth fixing are: bedding laid too wet, no drainage path under the pavement, irrigation spraying directly onto the surface, and paving installed before the substrate has cured. A free-draining bedding layer, a fall to a linear drain, and keeping sprinklers off the paving solve most cases. Surface sealers applied too early trap moisture and make it worse.
For external paving the joints that matter are the ones that let the pavement move independently of the structure: at every change of substrate, around columns and manholes, and at the perimeter. For a continuous run of porcelain or stone, a common figure is a movement joint every 6–8 metres, with the exact spacing taken from the tile manufacturer's data and the temperature range on site. Joints filled with a rigid mortar defeat the purpose — they must be compressible and sealed against water.
The pattern is a structural choice as much as a visual one. A stack bond on a flexible bedding has no interlock and will rut under vehicle load; a 90-degree herringbone gives the best load spread and is the default for driveways and service yards. For pedestrian plazas a running bond or a basket weave is normal, and the pattern must be drawn to the actual setting-out, because starting from a corner instead of a centre line leaves a cut course exactly where the entrance is. Specify the joint width and the laying pattern together — one without the other cannot be inspected.
Send the city, the scope and the date the submittal is due — Evan replies personally after reviewing your enquiry.
Prefer to ask first? Ask the AI assistant — answers in seconds →
Generated live from configuration on 2026-11-05 (content reviewed 2026-11-04) — approval authorities, codes and test basis update automatically when our standards file changes. © YY Design Group (HK) Co. Ltd